• APPROVED
  • WALKIE TALKIE TO FREESPEAK II BASE-II CONFIGURATION VIA CCM

     

    PINOUT: Kenwood Walkie Talkie 5 Pin K Cable to FreeSpeak II Base II - RJ45 and DB-15 Connector

     

    1. Log into the your FreeSpeak II Base II CCM

    2. Default login credentials: ID: admin / PW: admin

     

    Assignment Setting:

    1. Navigate to “Assignment” tab

    2. Select the desire “Channel” (e.g Channel 1)

    3. Select and add “+the “4W-Port” connected to the walkie talkie

     

     

     

     

     

     

     

     

    4-Wire Port Setting:

    1. Navigate to “Device” tab

    2. Select “Ports

    3. Select the “4W-Port” connected to the walkie talkie

    4. Select “Port Function - ‘To Matrix

     

     

     

     

     

     

     

     

     

    GPIO Setting:

    1. Navigate to “Device” tab

    2. Select “General

    3. Select “GPO1” 

    4. Select “Source” to the channel assigned “Destination” to the walkie talkie (e.g Channel 1)

    5. Select “+” to create new “GPO” (Control Events)

      1. Source = Channel assigned to the walkie talkie (e.g Channel 1)

      2. Destination = 4W-Port connected to the walkie talkie (e.g 4W-Port 1)

      3. Action Type = Call (4W-Port 1 receive call) - Press “Talk” on FSII Base Channel 1 to send audio to the Walkie Talkie.

     

    CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


    This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


    The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.