Wireless: FSII IPT (19) Fans & Filters

Wireless: FSII IPT (19) Fans & Filters

IP Transceiver fans and filters

 

The IPT operating temperature is 0 to 45°C in shaded conditions.

Each transceiver contains two fans which activate when the IPT internal temperature reaches 55°C. If the internal temperature reaches 60°C, LED 1 will flash red at 2 Hz.

You should periodically check that the fans function correctly, and if necessary replace them.

If a fan fails, LED 1 flashes red at 4 Hz.

 

Each transceiver contains two internal filters and one external filter to protect the device from dust and other atmospheric debris.

You should periodically clean the filters with warm water and let them dry. Replace them if they are damaged.

Clear-Com recommends that you clean the internal filters every 1 to 2 months, and that you clean the external filter every 18 to 24 months.

 

FSII IPT Fans and Filters.png
Internal view of fans and filters

 

FSII IP LEDs.png
FSII IPT LEDs

 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.