Question:

I need a confirmation about registering 4 beltpacks on one base, and using all 4 beltpacks.

Is it just a matter of setting 2 belt packs in latch operation and the other 2 in non-latch mode so that only those two will work in"half-duplex" mode?

 

Answers:
You can register up to 15 Bps on the DX300 base but only 3 can talk at the same time(see link to DX300manual).

You set each BP to talk on Channel X or Channel O or both channels.

The BP will listen to the channel it has been selected to talk on, so it works full duplex on that channel


Yes, you can set the BP to be latching or non-latching operation

For DX-300 you get the added function of both relay and 4-wire operation 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.