AES67 Requirements and Recommendations

Clear-Com does not aim to verify Ethernet switch manufacturers or a customer's network topology. Though Clear-Com Engineering has tested specific switches for certain workflows, this information is for guidance only.

The standard AES67 network is a bridging compliance which allows any AES67 compliant device to participate with other compliant devices on a network in order to transport high quality audio over IP (AoIP.) Unlike Dante, this requires a more thorough understanding of the network topology since the mechanics are less automated.

Clear-Com has provided a thorough User Guide that explains what is necessary for a AES67 network, what is required and what has been tested.

AES67 Guide

 

 

IPA and IP-Transceiver Networking Guide

 

 

Features Required:

  • 1Gb (or more) bandwidth for every port

  • Layer III - Can perform at or near wire speed, but also acts as a router because it has IP routing intelligence built in.

  • Switching capacity equal to 2x number of ports (Tx/Rx). To exemplify this, if you purchase a 10-port switch, it should have a switching capacity of 20 Gb/s.

  • EEE (Energy Efficient Ethernet) or Green Ethernet needs to be disabled.

  • QoS - Quality of Service prioritization of audio traffic.

  • Fiber to Copper conversion preferable using the SFP/mini-GBIC form factor.

  • IGMP snooping must be properly configured.

Recommended Features:

  • PTP Aware Switches (that support Boundary Clock or Transparent Clock Mode.)

  • Dedicated PTP GrandMaster Clock (separate from the IPA card.)

Back to AoIP Network Requirements and Recommendations Home Page

 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.