Question:  The LED marked "-" (analog supply) on my IMF-3 is not lit.  With the LED off, has my IMF negative rail failed?
Answer: 
1.)  Check the fuse block on the front panel of the PSU-101 power supply unit.  To open the fuse block gently press down on the top of the block and then pull the block forward to expose the fuse.  Check fuse and replace if necessary with a Bussman GMC3A fuse.
2.)  Verify that the power cord is properly connected to the PSU-101. 
3.)  Check that the Jones power cable is properly connected between the PSU-101 and IMF-3 frame. 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.