Wireless: Why when I have 4 Tempest belt packs on and when I turn on the 5th Tempest belt pack, the display tells me that slot is unavailable

Each BeltStation has a slot number assigned.  By default the number is 1.  If you do not change these numbers on each belt they are all set to 1.
The basestation has two display modes: In Dynamic mode the system ignores this setting.In Static mode it uses these slot numbers for the display assignment for the 5 belts on the base, one belt per slot 1-5.
Example: Name the BeltStations "Pac 1" through "Pac 5"
Dynamic mode:BeltStations will show up as 1-5 on the display They will be sorted by Alpha-numeric order based on the belt nameTurn off "Pac 3"Display will show Pac 1, Pac 2, Pac 4, Pac 5, and the last slot #5 will be empty.Turn on Pac 3 and they will all realign.
Static mode:Set slot #'s on all BeltStationsThey will now be displayed based on slot number regardless of name.Turn off "Pac 3"The middle display (slot 3) will now be blank and all BeltStations will stay in their original position.
There are applications and reasons for modes both.  If the slots are not assigned correctly on the BeltStations and the basestation display mode was changed from dynamic to static. Then its you're likely to see the "..slot is unavailable.." message
The slot assignment setting is in the Belt Settings menu on the BeltStations.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.