use tools like PTP trackhound , Multi-cast Hammer , Wireshark to assit you
check NMOS controller:
Clearcom MQTT broker port is 8855,check if the nmos controller includes 8855 port.
check E-IPA reports same state as NMOS controller
if card not in NMOS controller, web browser to <CARD-IP-ADDRESS>:8855 ->
if you see the NMOS tree (standard XML output) then the IPA card is correctly enabled .
If it times out... check your EHX config, IPA card is in NMOS mode, check IP address/ subnet mask of your AOIP LAN port, and the IPA card is running the correct firmware. This should be V13.1 or later to support NMOS mode
...