AOIP: Basic NMOS troubleshooting

EHX v13.1 introduces NMOS (is-4/ is-5) functionality for E- IPA cards

 

See https://www.amwa.tv/nmos-overview for overview

see https://www.youtube.com/playlist?list=PLgnZ0j-A0jYBJe09C1AaOrIWcMGFenO4Z for testing NMOS using Easy-NMOS

 

NMOS allows a 3rd party controller to set up routes between AES67 devises

Each AEs67 device/ node publishes it capabilities to the controller , can then make and & break routes AES67 streams without them have to exchange SDP files

 

troubleshooting

follow standard AES67 and PTP troubleshooting steps

use tools like PTP trackhound , Multi-cast Hammer , Wireshark to assit you

 

  • check NMOS controller:

    • Clearcom MQTT broker port is 8855,check if the nmos controller includes 8855 port.

  • check E-IPA reports same state as NMOS controller

  • if card not in NMOS controller, web browser to <CARD-IP-ADDRESS>:8855 ->

  • if you see the NMOS tree (standard XML output) then the IPA card is correctly enabled .

  • If it times out... check your EHX config, IPA card is in NMOS mode, check IP address/ subnet mask of your AOIP LAN port, and the IPA card is running the correct firmware. This should be V13.1 or later to support NMOS mode

 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.