Up to 5 beltpacks connected to a single antenna which generates local sync if none provided. E1 to E1 goes over IP adapter.
Info |
---|
The following are units have been seen to work for E1 over Ethernet – not a particular recommendation: |
IPT antennas (with < 10ms delay for audio packets)
Same subnet, separate VLAN, good PTPv2 over network (possibly with boundary clock) – works from v10.
Same subnet, PTPv2 provided to both locations separately using GNSS/GPS-locked PTP – works from v10.
Different subnet, different VLAN, PTPv2 provided to both locations separately using GNSS/GPS-locked PTP:
Use IP addresses rather than mDNS for addressing.
Layer 2 routing with local switch providing MAC forwarding - works from v11.1
Layer 3 routing, no switch assistance – works from 12v12.3 4 (IPA: 4.38.63.0 / IPT: 4.13.67.2 or better)
The following are units I’ve seen working for E1 over Ethernet – not a particular recommendation:
https://www.ctcu.com/en/tdm-over-ethernet.html
Clear-Com: Network Considerations for Routing Clear-Com AES67 Streams across Layer 3
Be aware that Ethernet over E1 is a product category too, and those tend to have more search results.