Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Question:  Can I assign both ports of a 4-wire moduleto the same channel on a Helixnet base?  Answer: yes you can assign both ports of a 4-wire module tothe same channel on a Helixnet base.In fact a Helixnet base has 3 expansion slots so if you had3x 4-wire modules installed then you could assign all 6 ports to the samechannel Also if you linked another Helixnet base then you can alsoassign all the 4wire module ports in the 2nd Helixnet base to thesame chnl on the 1st Helixnet base   NOTE: you need to take care not to create any external audioloops as this may cause feedback (especially if you are using Helixnet 2-wire PLmodules)