Digital Partyline: Can I assign more than one 4-wire module port to a Helixnet PL channel?

Question:  Can I assign both ports of a 4-wire moduleto the same channel on a Helixnet base?  Answer: yes you can assign both ports of a 4-wire module tothe same channel on a Helixnet base.In fact a Helixnet base has 3 expansion slots so if you had3x 4-wire modules installed then you could assign all 6 ports to the samechannel Also if you linked another Helixnet base then you can alsoassign all the 4wire module ports in the 2nd Helixnet base to thesame chnl on the 1st Helixnet base   NOTE: you need to take care not to create any external audioloops as this may cause feedback (especially if you are using Helixnet 2-wire PLmodules) 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.