Clear-Com uses the ETSI DECT Sync signal. Below this text is an excerpt from the spec.

This signal appears across pins 3 and 6 of the DECT Ref OutRJ-45 connector on the rear of the E-Que.  Pin 3 is + It’s  

It’s a 100 HZ pulse train with the positive pulsesabout pulses about 880 usec µs wide, and every 16th pulse is 2640 usecµs , three timesas times as wide.  This same signal also appears across pins 3 and 6 of thetransceiver the transceiver RJ-45.    On  

On a FSII base, the same signal appears across pins 1 and 2of the Synch Out RJ-45. B 

B.2.1 Synchronization signal

  • The synchronization signal  is a 100 Hz signal having positive pulses of width between 5 μs and1 ms, except for frame 0 (every 16th pulse), which has a pulse width between 2 ms and 5 ms. This signal establishes the10 ms DECT frame interval and the 160 ms DECT multiframe interval.

  • The synchronization signal shall have a long term frequency accuracy of better than ± 5 ppm (nominal conditions) or± 10 ppm (extreme conditions).

  • As the wave form is asymmetric, devices can establish proper timing relations in the event that the differential pair

...

  • of input signal wires is (improperly) connected (pair inversion).

  • The random phase jitter on the falling edge of the synchronization signal shall not exceed 0,5 μs rms. The

...

  • differential amplitude shall be greater than 400 mV peak to peak.