How are the ST2110 audio streams defined on the E-IPA card
How are audio streams defined in EHX for the E-IPA card
Are the multicast addresses are freely configurable?
What about the others parameters of the streams?
Is it only with 1 audio channel streams, or 2 audio channel streams are also possible?
Answer: Using EHX v12.2
The specifications below may change in later versions of EHX , please refer to the release note , related to your EHX release
The IPA card uses the SAP protocol and also supports manual entry (import and export) of SDP files .
The multicast addresses are freely configurable
The card operates to SMPTE-2110 conformance level a & b
TX Streams can be from 1–4 channels per stream
RX Streams can be from 1-8 channels per stream
The E-IPA card will support upto 64x streams per card this includes
3rd party AEs67/ ST2110 stream (these can be purchased in blocks 8 )
internal AES67 streams used for Iris and IPT connections
Related content
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.