E1 Transceivers Disappear After Upgrade to 12.2 or 12.4 - BPs may not register

On some systems using E1 transceivers and E-Que cards, upgrading from earlier versions of EHX to V12.2 or V12.4 causes an issue with E1 transceivers not being imported correctly. You may see the message “"unable to get slot pointer for RPN x” in the event log. The transceivers will not function in this state.

You may also have issues registering FS II BPs.

The solution to this is to request from support@clearcom.com the patched version of

  • EHX12.2, Patch # 12.2.0.17, EHX setup version 24.19.1.5,

  • EHX12.4, Patch # 009, EHX Setup version 28.12.1.3.

These patches were released on Aug 16 2022.

 

 

 

 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.