LQ / FOR-22 to GeneralDynamics URC-200
The tables below are untested options.
The drawings below have been verified and implemented in the field as of 8.2022
Handset J4 (This is a male 6-pin U-229, so we need a female connector):
URC-200 J4 Pin | Purpose | LQ Pin | LQ Purpose |
---|---|---|---|
A | Ground | 9 and 6 | Relay Common and Line Out - |
B | Audio Out (Plain Text) | 2 | Line In + |
C | PTT | 5 | Relay N/O |
D | MIC in (Plain Text) | 1 | Line Out + |
E | Audio Out (Plain Text) | Duplicate of B | Line In - |
F | Retransmit Squelch | 8 | GPI / COR |
X-Mode J2 (MS3114E16-26S)
Connector can be sourced here (or find similar): https://www.digikey.com/en/products/detail/milspecwest-llc/MSW06E16-26P-SR/15785838
URC-200 J2 Pin | Purpose | LQ Pin | LQ Purpose |
---|---|---|---|
D | Ground | 9 and 6 | Relay Common and Line Out - |
E | Audio Out (Plain Text) | 2 | Line In + |
F | PTT | 5 | Relay N/O |
C | MIC in (Plain Text) | 1 | Line Out + |
U | Retransmit Squelch | 8 | GPI / COR |
Visio
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.