Maximum number of E-IPA cards I can have in my EHX matrix?

Maximum number of E-IPA cards I can have in my EHX matrix?

Please table below:

EHX v12.1 allows 

EHX v12.1 allows 

Delta

Median

Omega

PS=N/A

PS=720379Z

PS=720379Z

3

4

5

(requires forced air cooling)

 

  • Other EHX versions might have smaller limits

  • You will also need to know what other cards are being used and then check the latest HX power calculator( from Eclipse HX System Power Calculator )

We recommend forced air cooling for all matrices but for the OMEGA frame forced air cooling is mandatary when using x5 IPA cards in the Omega frame

Tip: To spread the heat map load some customers should ensure there is 1 matrix-slot gap between IPA cards.

example #1 IPA <empty slot > IPA <empty slot>

example #2 IPA <MVX > IPA <MVX>

 

The maximum card limit for an Omega frame is 5x EIPA and or IVC/EQUE cards

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.