Partyline: Can the KB-702 talk switch be permanently enabled to the "On" position?

Question:  I need modification instructions to mod a KB-702 to permanently latch on the TALK button. Customer will only be using the KB-702 with a HS-6 and wants to only use the trigger switch on the handset to talk with. They want the KB-702 "TALK" button permanently latched on.
Answer:  The modification shown below to the KB-702 circuit board will permanently enable the talk switch to the “on” activated state, this will allow the operator to key the talk path on / off using the HS-6 handset button or a PT-7 handmic.
The modification drawing shows the user how to solder an insulated wire jumper between the two solder pads shown with the orange arrows.
Please note that performing the modification can void the warranty on the KB-702 if the modification is not performed correctly / damages the pcb.
The drawing is also attached below as a PDF document.

















  File Modified

PDF File KB-702 talk sw ON modification.pdf KB-702 talk sw ON modification.pdf

Apr 06, 2019 by Administrator

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.