Voice2: Voice unit keeps dropping the line and locking up

Voice2 units keep dropping line and locking up. 
Customer was advised to change the following Voice2 unit settings
a) change disconnect timer from 40 sec to 3-7 seconds on both server and client 
b) change the codec to a Speex either 34.2 or 42.2 (these offer similar performance to G722 but are more resilient to errors on the line ) 
c) make sure the trace level on both server and client is set back to 1 
d) make sure jitter buffers are set between 200ms - 500ms 
This resulted in the units not locking up 
Note: See other solutions on Voice2 unit

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.