Matrix: How does the VOX action work

How does the VOX action work
Each MVX-A16 port on the matrix has a VOX (Voice Operated Switch) detector circuit (similar to a noise gate)
When the audio entering the input of the port goes above the threshold level of the VOX - (the setting is adjustable using the ECS configuration software from -45db to 0db)
The VOX will trigger a Control action . The Control action can be programmed to make audio routes or fire relays.
Extract from ECS manual:
The VOX Action allows a Control to be attached to a port. Whenever the audio level at the Port reaches the Audio Detection Threshold defined in Voice Operated Switch the Control attachments such as Relays, Routes or Speed Dials, are activated.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.