Matrix: V Series panel listen again function not working on one particular matrix port

Each systempanel port has an adjustable setting which determines how long "LISTEN AGAIN" recordings arestored for.... if this is set to zero then panels will not store messages.
Thissetting can be adjusted in both ECS and locally at the panel ... the settingmade at the panel takes priority.
So we needto make sure that the panel settings havea non-zero value.
Thesequence at the panel is :-Press MENUPress LOCAL PREFPress TIMEOUTSThe lower display will show “MSG A DEL       #” (Where ## is in the range of 0-99 )
The smallarrow keys beneath the display will allow the setting to be changed.
A value of0 .... inhibits recordingsA value of1 .... deletes recording after 1 Minute etc
(Notealthough the setting is made at the panel it is stored in the Matrix ... So apanel which is working fine on one port can stop working on a different port)

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.