Helixnet: HMS master station shows “Duplicate Ethernet connections”


We have experienced an issue 2 (maybe 3) times between recently.  This issue caused the system to stop working until reboot.The master station shows an error message on front panel “duplicate Ethernet connections” and the remote stations lose their profiles.The error states to check for “duplicate Ethernet connections”.The system starts working again after a simple reboot of master station.
SolutionThis happens when the on-board Ethernet switch detects 20000 broadcast or 20000 multicast packets within 2 seconds on the network. The Ethernet port is turned off until a reboot is performed. This could happen if there is a duplicate IP address of if there is a network loop somewhere. Unless there is also something that occasionally floods the network with broadcast or multicast traffic

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.