Matrix IVC-32-HX to LQ Devices bandwidth Requirement
Question: What is the LQ to IVC-32-HX data bandwidth in each direction?
All IVC-32-HX related IP panels (IVC mode), Agent-IC, IP trunk and IP directs needs up to 140kbps for one-way (approx 280kps full duplex) . Would LQ devices linking to IVC-32-HX be the same?
Answer: Yes it is the same 140kbps each direction, 280kbps per full duplex link for LQ to IVC connection See both attachments.
All IVC-mode related connections using IP panels (IVC mode), Agent-IC, IP trunk and IP directs needs up to 140kbps for one-way (approx 280kps full duplex) .
This applies to IVC-32 cards or E-IPA card
Example:
IVC-mode the bandwidth requirement is 280Kb/s per channel.
If you have an IP panel with 2 additional channels then you have 3 channels in total = 3x 280Kbs per Remote panel
Related content
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.