How can I hear the audio from my AB100 on a panel connected to a M+3 system

You can permanently hear the audio coming from a 4w port on a single station by adding a forced listen. Take for example, - an AB100 console connected to port 3 on the matrix, - an ICS102 station, connected to port 17.
To make a forced listen in PGM_WIN, go to Configure --> Local Advanced.
From the list on the left, select "station" and highlight the required station, in this case port 17.From the list on the right select "interfaces" look for port 3 and check the box under the "Forced Listen" column.
This will permanently route the audio from the AB100 to the ICS102 and because the AB100 has a talkback button, then the audio will only be heard when that talkback button is pushed.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.