Matrix: Can one REDUNDANT IVC-32 card support fail over for more than one card?

Yes! The card properties for the IVC-32 (Redundant) card allow you to specify whichIVC-32 to provide redundancy for several cards. Set as many cards as your frame can support (up to 6 on an Omega Eclipse frame), minus one... that "one" will be your REDUNDANT card.  

In SET CARD TYPE on, in the slot on the CARDS AND PORTS CARD that you wish it to use, set it as an IVC-32 (Redundant) card.  In CARD PROPERTIES, choose the live IVC-32 cards you wish it to monitor and be a fail over for, APPLY CHANGES with a reset and you're done.  Just finish programming the live cards as you would and leave the redundant card to monitor the other cards.  

If it sees a failure on any of the cards you have assigned it to be redundant to, it will take over for that card, with all its settings and attributes, in the unlikely event of a failure of that card.See attached.

  File Modified

PDF File IVC 32 redundancy.pdf IVC 32 redundancy.pdf

Apr 06, 2019 by Administrator

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.