Partyline: Which CAT-5 cable pairs should I use when wiring a FIM-202D to a remote IF4W4?

After configuring a port as DIRECT in ECS, you would take that port to the MATRIX side of the local FIM-202D. At the remote end, when connecting the remote FIM-202D via the PANEL RJ45, you'd use pins 4 & 5 on the CAT-5 cable (The blue pair) to the IF4W4's receive side and pins 3 & 6 (the green pair) to the IF4W4's transmit side.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.