Matrix: How to configure a latching footswitch for V-Series panels

The ECS function "Activate Talk Switch - 1" and  "Activate Talk Switch - 2" for Logic Input 1 and Logic Input 2 on V-Series is by design always non-latching, even if a normal key to the destination is allowed to be latch. To work around this choose "Select Route" for the Logic Input instead. On the following Route Selector screen, pick the destination you would like the foot switch to activate a route to.This makes the panel GPI follow the key action like it was a normal key including latch / non-latch.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.