Matrix: How are Logic Maestro diagrams associated (saved) with ECS configurations

Logic Maestro How are Logic Maestro diagrams associated with ECS configurations 
When LogicMaestro is selected Enable (ticked) this will affect whatever PC mapconfiguration is loaded in ECS. A logic maestro diagram it self is not part of the PC mapconfiguration but exists above all configurations. So if you make a change tothe Logic diagram, that change is not saved specifically to that configuration but is downloaded as part of whatever ECS map is active at the time on the PC
Logic Editing:Part One Enable  Logic   If you edit a logic and select Enable  this action will effect whatever PC mapconfiguration you are about to send (download) into the Matrix. 
See example below:1)     I have here a map called: Test_IFB_Map_1
2)     I  edit alogic :
 Xpt Trigger Action > X-point talk between Panel A to Panel B    &     Xpt Action > Inhibit Panel C not to talk to PanelA
       


Note: ifI send the PC map (Test_IFB_Map_1) into the matrix, the logic will also be sendwith the map and the effect of the logic will take place.            

Logic Editing:Part two1)     If I make a copy of the PC map (Test_IFB_Map_1)  and I give it a new name: Test_ Copy_ MapIf I just make a download then the logic from example part one will apply : If want the same logic to affect Panel B instead I have to edit the logic diagram
2)     I have to also re edit the Logic: Xpt TriggerAction > X-point talk between Panel Ato Panel B   &       Xpt Action> Inhibit Panel C not to talk to Panel B      

Note: if I send the new PC map (TEST_Copy_Map)into the matrix, the logic will also be sent with the map and the new effect ofthe logic will take place.      











In summary using ECS 524 : Logic maestro diagrams are downloaded alongside the main map configuration. This means that if you use Configuration manager to switch from map-1 to map-2 then the currently active  / enabled logic maestro diagrams from map-1 will be downloaded with map-2 The logic maestro diagrams are in effect independent of the maps. This was a design feature to allow users to switch to different configurations but still use the same logic diagrams.  
note# 1If map-2 has changed any port / group names from map-1 then the logic maestro diagrams which use the old port names will not work and an error message will be shown when you try to download.
note#2In ECS we have the concept of projects . A project can hold a number of different map configurations but only one set of logic diagrams (enabled or non-enabled)When you export a project you export all the maps and logic diagrams associated with that projectA different project can hold a set of different maps and different set of logic diagrams as compared to another project.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.