Matrix: Can a Matrix +2 version ICS-62 panel work on a Matrix +3 frame?

The older ICS-62 panels that are configured for Matrix +2 systems would need to have their Com cards replaced with
Matrix +3 versions Com-1A PN 710464 and the EPROM IC8 replaced with a Matrix +3 EPROM PN 710416 in order
to be compatible with analog port cards on a Matrix +3 frame.  
Matrix +3 is a legacy platform that was discontinued back in 2008, so it may not be possible to upgrade or convert
digital versions to analog version due to the obsolescent hardware required.  Check with our Alameda Service Center
to confirm if these options are still available.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.