Matrix: GPI-6 does not work along side RLY-6. Cabling GPI-6 and RLY-6 Modules

GPI-6 modules and RLY-6 modules are cabled in a daisy chain from the GPI/RLY output on the back of the CPU card to first module. It is essential that the GPI modules are the first devices in the chain. If they are not then the GPI will not function.The module will be powered and the test buttons will respond but the signal will not reach the Matrix.
Cable as per the example below. Cable length must not exceed 6 meters in total.










































































CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.