Using Arcadia R2 firmware you are not able to set the Arcadia into PTP follower mode

...

Note

For Arcadia R3, even when in PTP follower mode, IPTs get there PTP settings from the Arcadia; they are not inherited from the Clock Leader (GM). The PTP settings that the Arcadia sends to the IPT antennas are fixed by the Arcadia’s own PTP settings (see above). Therefore the Clock Leader (GM) settings need to match the Arcadia PTP settings.

PTP Clocking: reference/follower only mode

 From R3.0 and above, the Arcadia and Edge base-stations can function as either PTP reference or follower only clock (enable/disable PTP follower mode in CCM > Hardware > Host > Network > [select the LAN that has been configured for AES67] > PTP Follower Mode).

When the Arcadia station is in PTP follower mode, the clock settings on the reference clock must match those of the Arcadia station, as Arcadia PTP settings cannot be changed at the current time.

Clock priority in PTP reference mode (A & B) on the intercom stations is set to 127.

...

Network Jitter Tolerance: < 1μs required for IPT RF Synchronization

...

Management: DSCP=0, Best Effort (DF)

PTP Parameters:

PTP domain: 0

Priority 1: 127

Priority 2: 128

...

Sync rate: 8/s

Media Profile : AES67 Media profile

Restrictions: The AES67 VLAN used by Arcadia to connect to IPTs

...