Answer: When using the HXII-BP beltpack as a Digital Power Line beltpack, the 20 beltpack limitation remains the same (10 beltpacks per digital power line, 2 digital power lines per HMS main station).
When using the HXII-BP as a PoE beltpack, more than twenty total beltpacks may be on the system. There is a limit of 60 devices may be connected to a single HelixNet system.
question Question # 2: Is there any data limit that we need to be aware of that would reduce the number of HXII-BP / desktops / HRM-4X remote stations that could be connected via Ethernet?- How about CAT-5 / 6 cabling limits? Anything that we should be aware of?
...