from early versions to the newest EHX 12.2, field testing that, if customer have manually import the SDP of RX steam . plase If a customer manually imports the SDP file into EHX for RX steam . Please follow this rule:

the RX SDP needs to have unique session ID.,

The 'o' field and the 's' field should be unique in the SDP

The same session ID may cause can result in the audio stream can’t be not being decoded and the EHX event logs show error message: TIME

“TIME OUT-BACH respones is slowCheck : slow”

Using EHX, check the SDP viewer--cofigured configured-Rx

...

Manual moidification from Manually modify the SDP file using the AoIP SDP editor window:

...

See How to Interpret the SMPTE2110 SDP File Generated by EHX , for details on SDP file content