How many PTPv2 clients can the E-IPA service when acting as a PTPv2 Leader
This article has been updated to use the new terminology instead
PTPv2 Leader - formerly known as Grand Master (GM)
PTPv2 Follower - formerly known as Slave / Client
The E-IPA card can be configured to be a PTPv2 Leader on an AES67 / ST2110-30 network or it can be set to be a PTPv2 follower only.
The PTPv2 Leader unit on an AES67 / ST2110-30 network sends PTP sync packets to each PTP follower unit in its PTPv2 domain.
There is a finite number of PTPv2 follower devices any PTPv2 Leader clock device can support.
The E-IPA card can service approx. 20 PTP follower units when acting as a Leader clock. This number includes any Clear-Com and other 3rd party devices.
Updated Jan 26, 2026
Clear-Com recommendation for systems with more than 20 PTPv2 clients
use an external, GPS-locked PTPv2 Leader clock unit (like the Trilogy Mentor RG)
in combination with PTPv2 aware, boundary clock capable ethernet network switches
setup your external Leader clock to operate in PTPv2 two-step message exchange mode
Jul 11, 2024
E-IPA cards running v8.61.63.0 firmware support PTPv2 2-step message exchange only.