LQ Lab Series 5.3 - LQ SIP to Eclipse IPA Intergration
This module explains how to connect an already registered LQ SIP account to an Eclipse HX Matrix through an E-IPA card. SIP registration and I.V. Direct are separate paths: SIP registers the LQ account with the SIP server, while I.V. Direct carries the LQ SIP audio between the LQ and the Eclipse Matrix.
1. Purpose
Use this procedure after Module 5.2 is complete and the LQ SIP account is already registered and online.
The two-sided workflow is:
SIP server ← SIP registration → LQ ← I.V. Direct → E-IPA / Eclipse MatrixDo not repeat SIP registration here. Channel assignment, EHX key configuration, and end-to-end call testing continue in Module 5.4.
2. Before You Start
Confirm these items before configuring the integration:
LQ SIP account is registered and online.
LQ CCM is accessible.
EHX is accessible.
E-IPA card is online and available.
E-IPA IP address is known.
LQ can reach the E-IPA over the network.
An available E-IPA port has been identified.
Matching user ID and password are available.
The following values are lab examples only. Replace them with the actual system values for your installation.
Item | Example |
|---|---|
E-IPA IP address | 192.168.1.4 |
I.V. Direct port | 6001 |
User ID | lq1 |
Password | 1234 |
3. Connection Diagram
4. Configure the SIP (LQ) Port in EHX
Configure the E-IPA port that will accept the I.V. Direct connection from LQ.
Open EHX.
Go to Cards and Ports and select the E-IPA card.
Select + Port.
Set Port Function to SIP (LQ).
Enter a Label
Open IP Port Options.
Enter the user ID and password.
Select the correct network connection. (LAN/WAN/Internet)
Apply the configuration using Apply Map to Matrix.
Use the supplied EHX screenshots beside the relevant steps.
Field | Example |
|---|---|
Port Function | SIP (LQ) |
Label | SIP GrandS |
User ID | lq1 |
Password | 1234 |
Network Connection | LAN |
Audio codec | G.722 |
The user ID and password are lab examples. They must match the I.V. Direct port configured in LQ CCM.
5. Create the E-IPA Remote System in LQ CCM
Add the E-IPA as an IVD remote system in LQ CCM.
Open LQ CCM.
Go to Accounts.
Select IVD.
Select + to add a remote system.
Enter a Label.
Enter the E-IPA IP address or hostname.
Enter the E-IPA I.V. Direct port.
Field | Example |
|---|---|
Label | IPA-C |
IP/Hostname | 192.168.1.4 |
Port | 6001 |
6001 is the example/default reference. Confirm the actual port against the E-IPA configuration.
6. Add the I.V. Direct Port
Add the LQ-side I.V. Direct port under the E-IPA remote system.
Add a port under the E-IPA remote system.
Enter a Label.
Enter the same User ID configured in EHX.
Enter the same Password configured in EHX.
Select the required LQ assignment.
Field | Example |
|---|---|
Label | E-IPA |
User ID | lq1 |
Password | 1234 |
LQ Assignment | LQ-R2W4-4W#1 |
Credentials are case-sensitive and must match exactly. These credentials are lab examples only.
7. Verify the I.V. Direct Connection
Check status in both LQ CCM and EHX.
Location | Expected indication |
|---|---|
LQ CCM SIP account | |
LQ CCM IVD account | |
EHX E-IPA port |
These indicators confirm connectivity only. They do not prove channel assignment, panel-key configuration, or bidirectional audio.
8. Common Problems and First Checks
Troubleshoot I.V. Direct separately from SIP. A registered SIP account does not prove that the E-IPA connection is working.
Problem | First check |
|---|---|
E-IPA host is unreachable | Check the E-IPA address, port, gateway, and network path. |
Incorrect username or password | Confirm that EHX and LQ CCM credentials match. |
EHX port remains offline | Confirm that the EHX map was applied. |
SIP is registered but E-IPA is offline | Troubleshoot I.V. Direct separately from SIP. |
Connection fails across a firewall | Confirm the configured port and required traffic are permitted. |
9. Verification Checklist
See https://clear-com.atlassian.net/wiki/spaces/SF/pages/1379827772