LQ Lab Series 3.3: 4-Wire to 2-Wire Partyline Integration

LQ Lab Series 3.3: 4-Wire to 2-Wire Partyline Integration

Purpose

This article explains how to integrate a known-good 4-wire device with a known-good 2-wire partyline system through linked LQ units.

Applies To

Lab example:

  • FreeSpeak II Base-II 4-wire Port A → LQ-4W2 4-wire Port A

  • LQ-R2W4 2-wire Port A → MS-702 / RS-701 partyline

Connection Diagram

Screenshot 2026-08-21 at 12.19.31.png

Diagram notes:

  • The FreeSpeak II Base-II connects to the LQ-4W2 using 4-wire audio.

  • The LQ-4W2 and LQ-R2W4 link over IP through the network switch.

  • The LQ-R2W4 connects to the MS-702 / RS-701 partyline using the 2-wire partyline port.

  • Audio passes only after the correct LQ ports are assigned to the same channel.

Before starting:

Confirm:

  • Both LQ units are powered and connected to the network.

  • The 2-wire (MS-704 Intercom Partyline) side operating normally.

  • The 4-wire (Freespeak II Base II System) side working normally.

  • The LQ IP address and CCM access are confirmed.

  • LQ (Master/Member) linking is healthy

  • The required 2-wire and 4-wire ports are identified.

  • Channel assignment is understood.

Step 1 - Confirm the 2-Wire Side

Confirm:

  • MS-702 / RS-701 partyline is powered.

  • The correct LQ 2-wire port is connected.

  • Partyline power and termination are correct.

  • Auto-Null has been completed.

  • The 2-wire port is ready for channel assignment.

Step 2 - Confirm the 4-Wire Side

Confirm:

  • FSII Base-II 4-wire Port A is connected to LQ-4W2 Port A.

  • FSII Base-II is configured to use the selected 4-wire port.

  • LQ 4-wire Port Function has been checked.

  • Input Gain and Output Gain are at a known baseline, for example 0 dB.

  • Audio from FSII Base-II can be verified at the LQ side.

Step 3 - Confirm LQ Linking

If two LQs are used:

  1. Open CCM.

  2. Go to Overview.

  3. Confirm both LQs appear in the same Link-Group.

  4. Confirm Link-Master and Link-Member are healthy.

  5. Confirm no link error is shown.

Step 4 - Assign Both Ports to the Same Channel

  1. Go to Assignments.

  2. Select the required channel.

  3. Assign the LQ-4W2 4-wire port to the channel.

  4. Assign the LQ-R2W4 2-wire port to the same channel.

  5. Save or apply the assignment.

Step 5 - Verify Audio Both Directions

  1. Talk from the FreeSpeak II side and confirm audio is heard on the 2-wire partyline side.

  2. Talk from the 2-wire partyline side and confirm audio is heard on the FreeSpeak II side.

  3. Check for one-way audio, low level, distortion, hum, or echo.

Additional note: You can also use the audio and call signal indicators in the Assignment page in CCM to confirm the audio and call signal.

Screenshot 2026-08-20 at 11.45.47.png
Green indicates that audio is passing through or active.
Screenshot 2026-08-20 at 11.50.19.png
Call signal indicator
Screenshot 2026-08-21 at 11.32.30.png

Common Problems and First Checks

Issue:

First Check

Issue:

First Check

LQs are linked but no audio passes

Check channel assignment. Linking alone does not route audio.

See:https://clear-com.atlassian.net/wiki/pages/resumedraft.action?draftId=4909269003&draftShareId=7e57857f-7505-4127-b716-07605cf0b8dd&atlOrigin=eyJpIjoiMzQ3NDAyMzgzNmRlNDE1NGIyNTNiNzkxZDc2NzViYjMiLCJwIjoiYyJ9

2-wire side has poor audio

Check power, termination, cable, and Auto-Null.

See: https://clear-com.atlassian.net/wiki/pages/resumedraft.action?draftId=4979032074&draftShareId=1fb80c3a-d663-4927-9997-402108405c02&atlOrigin=eyJpIjoiNDJmMGQ3OWI1YmU3NDJkNDkxNjU2MzU2YjgyNjllZDMiLCJwIjoiYyJ9

4-wire side has one-way audio

Check Port Function, cable direction, and FSII 4-wire port assignment.

See - https://clear-com.atlassian.net/wiki/pages/resumedraft.action?draftId=4992434180&draftShareId=323b7184-0320-4af2-a548-36aca69bc973&atlOrigin=eyJpIjoiYTY2NzNiYTRlMjVjNGFiZjg4NDA2MGI1NTY3ZTQyNTMiLCJwIjoiYyJ9

Audio is low or distorted

Confirm routing and direction first, then adjust input/output gain.

See - https://clear-com.atlassian.net/wiki/pages/resumedraft.action?draftId=4992434180&draftShareId=323b7184-0320-4af2-a548-36aca69bc973&atlOrigin=eyJpIjoiYTY2NzNiYTRlMjVjNGFiZjg4NDA2MGI1NTY3ZTQyNTMiLCJwIjoiYyJ9

CCM cannot be reached

Check LQ IP (Front Display), laptop IP and LQ are in the same subnet/VLAN.

See: https://clear-com.atlassian.net/wiki/pages/resumedraft.action?draftId=4901208122&draftShareId=41dbc6c5-f943-4a9c-b97b-a11b3c32e507&atlOrigin=eyJpIjoiYWY3NjdlNDI1ZjdiNDkxZTk5OGQxMjM4ZjIxMWRhMDgiLCJwIjoiYyJ9

https://clear-com.atlassian.net/wiki/pages/resumedraft.action?draftId=4901044288&draftShareId=5511526b-1c41-4a53-b0c7-b38a1afe26d0&atlOrigin=eyJpIjoiOTQzNzMyYTBmMmUwNGUyYTliMTc4NmE4NDA3MDlhZDYiLCJwIjoiYyJ9

 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.