LQ Lab Series 3.2: How a local 4-W Intercom System to LQ?

LQ Lab Series 3.2: How a local 4-W Intercom System to LQ?

Purpose

This article explains how to connect a local 4-wire device to an LQ 4-wire port and configure the basic CCM settings.

In this lab example, we will use a FreeSpeak II Base-II connected to an LQ-4W2.

The same basic method can also apply to Arcadia, Eclipse MVX, and other compatible 4-wire devices. Verify product-specific wiring and settings separately.

The main CCM setting to understand is Port Function.

Applies To

LQ model

Description

LQ model

Description

LQ-4W2

Portable model with 2 x 4-wire ports

LQ-4WG2

Portable model with 2 x 4-wire/GPIO ports

LQ-R4W8

Rackmount model with 8 x 4-wire ports

LQ-R2W4-4W4

Rackmount mixed model with 2-wire and 4-wire ports

LQ-R2W4-4WG4

Rackmount mixed model with 2-wire and 4-wire/GPIO ports

See: https://clear-com.atlassian.net/wiki/pages/resumedraft.action?draftId=4900945999&draftShareId=a0308123-07a2-47e8-b27b-6908e164f6d3&atlOrigin=eyJpIjoiN2YwYjU3ZTNhZmE4NDQxZWI4MjM1Mzk0NmIxNThlYTEiLCJwIjoiYyJ9

 

Connection Diagram

Screenshot 2026-08-21 at 12.07.26.png

Before you begin:

Make sure:

Step 1 - Connect the 4-Wire Device

  1. Connect the FreeSpeak II Base-II 4-wire Port A to the LQ-4W2 4-Wire Port A using the correct RJ54 4-wire audio cable

  2. Confirm the connection is secure and that the device is using 4-Wire Port A.

Step 2 - Open LQ CCM and Select the 4-Wire Port

Screenshot 2026-08-21 at 11.22.33.png
  1. Open CCM from the PC or laptop.

  2. Go to Device > Ports.

  3. Select the connected 4-wire port.

  4. Label it clearly, for example FSII 4W A.

Step 3 - Configure Port Function

Screenshot 2026-08-21 at 11.23.23.png

Port Function

Use When

Note

Port Function

Use When

Note

To Matrix

Connecting to a matrix-style 4-wire port, such as Eclipse MVX

This is the default setting

To Panel

Connecting to a device that requires talk/listen pin direction to be reversed

Use this if audio works one way only or the pin direction does not match

  • Port Function controls the 4-wire pin direction.

  • If audio is one-way, check Port Function before changing gain.

  • This is a physical audio direction setting, not a network setting.

Step 4 - Confirm Input and Output Gain

Screenshot 2026-08-21 at 11.24.09.png

Start with Input Gain 0 dB and Output Gain 0 dB. Adjust gain only after Port Function, and audio direction are confirmed.

Step 5 - Verify Audio and Call Signal

Screenshot 2026-08-21 at 11.32.30.png
  1. Speak from the FreeSpeak II Base-II to verify audio and call signal into the LQ.

  2. Confirm the corresponding CCM assignment shows a green indicator, as in the picture above.

Note: Because this setup has only one 4-wire device connected to the LQ, this procedure verifies audio in one direction only: FreeSpeak II to the LQ. The two-way audio test will be addressed in the next module, https://clear-com.atlassian.net/wiki/pages/resumedraft.action?draftId=4992499726&draftShareId=b062612b-9ea8-46db-93ae-44f7616d66c0&atlOrigin=eyJpIjoiZmJjNTMyZWVlNGRkNDgzMWI5ZjE1ZWJhNDQzOWJiZGQiLCJwIjoiYyJ9

Common Problems and First Checks

Issue:

First checks

Issue:

First checks

CCM cannot be reached

Check LQ IP (front Panel)

Confirm that the LQ and PC are in the same subnet/vlan.

Also see:

https://clear-com.atlassian.net/wiki/pages/resumedraft.action?draftId=4901208122&draftShareId=41dbc6c5-f943-4a9c-b97b-a11b3c32e507&atlOrigin=eyJpIjoiNDlmMWQ3ZThlMmNkNDU5NjgyMDYxMGY4MWRkNmIzMDAiLCJwIjoiYyJ9

https://clear-com.atlassian.net/wiki/pages/resumedraft.action?draftId=4901044288&draftShareId=5511526b-1c41-4a53-b0c7-b38a1afe26d0&atlOrigin=eyJpIjoiMTdjYWZiYWE0NmQ4NGQ0MThmODkxZmEwZjEyYWUxMzciLCJwIjoiYyJ9

No audio into LQ

Check cable direction, FSII 4-wire output, and LQ input path.

Check Port Function: To Matrix / To Panel.

Audio works on way only

Check Port Function: To Matrix/ To Panel before adjusting gain.

 

 

 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.