LQ Lab Series 3.1: How to connect LQ to 2-Wire Partyline? 2W Configuration, Termination & Auto-Null
Purpose
This article explains how to connect a 2-wire partyline system to an LQ 2-wire port. It covers the essential port settings, partyline power, termination, Auto-Null and audio verification.
Table of Contents
Applies To
This article applies to LQ models with local 2-wire partyline ports.
LQ Model | Notes |
|---|---|
| Portable model with 2 x 2-wire partyline ports |
| Rackmount model with 4 x 2-wire partyline ports |
| Rackmount mixed model with 4 x 2-wire and 4 x 4-wire ports |
| Rackmount mixed model with 4 x 2-wire and 4 x 4-wire/GPIO ports |
Connection Diagram
Before You Start
Make sure:
The correct 2-wire LQ model is selected.
LQ power and network connections are working.
The LQ IP address and CCM access are confirmed. See LQ Lab Series 1.2 - Initial IP Setup and CCM Access
Step 1 - Connect the 2-Wire Partyline
Connect the 2-wire partyline system to the correct LQ 2-wire port.
Example: MS-702 Channel A to LQ 2-wire Port A.Confirm that the correct 3-pin XLR cable is used.
Test the local 2-wire intercom before continuing.
Step 2 - Configure Power and Termination
Open LQ Core Configuration Manager (CCM) in a browser using the LQ IP address.
Go to Device > Ports.
Select the connected 2-wire port and confirm the port label.
Configure power:
If the connected partyline system already provides power, do not enable LQ power.
Enable LQ power only when connecting beltpacks or an interface that does not provide power.
Ensure that only one device supplies power to the 2-wire line.
Configure termination: Only one endpoint on the 2-wire line should be terminated. If an endpoint such as the MS-702 already has its termination switch enabled, do not enable termination on the LQ for that same line.
Step 3 - Assign the 2-Wire Port to a Channel and Run Auto-Null
Go to Assignments.
Find the local 2-wire port configured in Step 2.
Assign the port to the required channel.
Run Auto-Null after the port has been assigned and the final 2-wire load is connected.
Important: Before Auto-Null, make sure all talk buttons on the external partyline systems are off. Do not wear headsets during Auto-Null because the process may generate a loud hiss. Run Auto-Null again if the wiring, beltpack count, connected equipment, or power source changes.
For more information, see What level of dB attenuation can the LQ 2W auto-null achieve.
Step 4 - Verify Audio
Speak into the 2-wire partyline system using a headset or microphone.
Confirm that audio passes to the expected LQ channel, check the audio and call signal activity indication (Green Light) in the CCM Assignments tab,
If audio is missing, unclear, echoey, or distorted, check the channel assignment and Auto-Null before adjusting gain.
Common Problems and First Checks
Problem | First Check |
|---|---|
No audio | Confirm the 2-wire port is assigned to the correct LQ channel. |
Beltpack has no power | Confirm which device is supplying partyline power and check the LQ 2-wire power setting. |
Echo or poor null | Confirm the correct line is connected to the correct port, then run Auto-Null again. |
Low or distorted audio | Review port settings, cable condition, Input Gain, and Output Gain. |
CCM cannot be reached | Check the LQ IP address, PC IP address, subnet or VLAN, Ethernet link, and switch port. |
Key Rule
For 2-wire setup, confirm the physical connection, partyline power, termination, channel assignment, and Auto-Null before adjusting gain.