LQ Lab Series 3.1: How to connect LQ to 2-Wire Partyline? 2W Configuration, Termination & Auto-Null

LQ Lab Series 3.1: How to connect LQ to 2-Wire Partyline? 2W Configuration, Termination & Auto-Null

Purpose

This article explains how to connect a 2-wire partyline system to an LQ 2-wire port. It covers the essential port settings, partyline power, termination, Auto-Null and audio verification.

Applies To

This article applies to LQ models with local 2-wire partyline ports.

LQ Model

Notes

LQ Model

Notes

LQ-2W2

Portable model with 2 x 2-wire partyline ports

LQ-R2W4

Rackmount model with 4 x 2-wire partyline ports

LQ-R2W4-4W4

Rackmount mixed model with 4 x 2-wire and 4 x 4-wire ports

LQ-R2W4-4WG4

Rackmount mixed model with 4 x 2-wire and 4 x 4-wire/GPIO ports

Connection Diagram

Screenshot 2026-08-20 at 16.06.19.png

Before You Start

Make sure:

Step 1 - Connect the 2-Wire Partyline

  1. Connect the 2-wire partyline system to the correct LQ 2-wire port.
    Example: MS-702 Channel A to LQ 2-wire Port A.

  2. Confirm that the correct 3-pin XLR cable is used.

  3. Test the local 2-wire intercom before continuing.

Step 2 - Configure Power and Termination

Screenshot 2026-08-20 at 15.39.57.png
  1. Open LQ Core Configuration Manager (CCM) in a browser using the LQ IP address.

  2. Go to Device > Ports.

  3. Select the connected 2-wire port and confirm the port label.

  4. Configure power:

    • If the connected partyline system already provides power, do not enable LQ power.

    • Enable LQ power only when connecting beltpacks or an interface that does not provide power.

    • Ensure that only one device supplies power to the 2-wire line.

  5. Configure termination: Only one endpoint on the 2-wire line should be terminated. If an endpoint such as the MS-702 already has its termination switch enabled, do not enable termination on the LQ for that same line.

Step 3 - Assign the 2-Wire Port to a Channel and Run Auto-Null

  1. Go to Assignments.

  2. Find the local 2-wire port configured in Step 2.

  3. Assign the port to the required channel.

  4. Run Auto-Null after the port has been assigned and the final 2-wire load is connected.

Screenshot 2026-08-20 at 14.07.36.png

Important: Before Auto-Null, make sure all talk buttons on the external partyline systems are off. Do not wear headsets during Auto-Null because the process may generate a loud hiss. Run Auto-Null again if the wiring, beltpack count, connected equipment, or power source changes.

For more information, see What level of dB attenuation can the LQ 2W auto-null achieve.

Step 4 - Verify Audio

  1. Speak into the 2-wire partyline system using a headset or microphone.

  2. Confirm that audio passes to the expected LQ channel, check the audio and call signal activity indication (Green Light) in the CCM Assignments tab,

  3. If audio is missing, unclear, echoey, or distorted, check the channel assignment and Auto-Null before adjusting gain.

Screenshot 2026-08-20 at 11.45.47.png
Green indicates that audio is passing through or active.
Screenshot 2026-08-20 at 11.50.19.png
Call signal indicator

Common Problems and First Checks

Problem

First Check

Problem

First Check

No audio

Confirm the 2-wire port is assigned to the correct LQ channel.

Beltpack has no power

Confirm which device is supplying partyline power and check the LQ 2-wire power setting.

Echo or poor null

Confirm the correct line is connected to the correct port, then run Auto-Null again.

Low or distorted audio

Review port settings, cable condition, Input Gain, and Output Gain.

CCM cannot be reached

Check the LQ IP address, PC IP address, subnet or VLAN, Ethernet link, and switch port.

Key Rule

For 2-wire setup, confirm the physical connection, partyline power, termination, channel assignment, and Auto-Null before adjusting gain.

https://clear-com.atlassian.net/wiki/pages/resumedraft.action?draftId=4979032074&draftShareId=1fb80c3a-d663-4927-9997-402108405c02&atlOrigin=eyJpIjoiYWNiYTA5OTE4MDdmNGFjNTkzNmYwZTRkZjI1NjQ0MDUiLCJwIjoiYyJ9

 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.