LQ: Accessing to CCM
Purpose
Use this article when setting up a new or reset Clear-Com LQ unit for the first time.
The goal is to access CCM, confirm network access, and configure the LQ with the correct static IP address before linking or further configuration.
Physical Layer / Power Check
Confirm the LQ is powered correctly.
Portable LQ units can be powered by PoE when connected to a PoE-capable switch or PoE injector.
Rackmount LQ-R units require PSU power.
Method 1: Direct PC to LQ Using Link-Local IP
Steps:
Connect the PC directly to the LQ LAN1 port.
Power on the LQ via PSU
Check the LQ front panel for the IP address.
If the LQ IP starts with
169.254, set the PC Ethernet adapter to a matching169.254.x.xaddress.Open a browser.
Enter the LQ IP address - e.g
169.254.100.100Log in to CCM.
Default Username: admin
Default Password: Check the LQ Front panel menu > Networking > CCM Password>
Method 2: LQ Connected to Network Switch with DHCP (Preferred)
Steps:
Connect the LQ LAN1/POE port to the network switch. *If you are using the LQ-R model, PSU is required to power the unit.
Connect the PC to the same switch or same VLan.
Power on the LQ.
Confirm the LQ is set to DHCP
Front panel menu > Networking > Edit > DHCP > Enable
Check the LQ front panel for the DHCP IP address.
Open a browser.
Enter the LQ IP address - e.g
192.168.1.100Log in to CCM.
Default Username:
adminDefault Password: Check the LQ Front panel menu > Networking > CCM Password>
The setup is complete when:
LQ CCM is accesible