LQ Lab Series 2.1: Master and Member Group-Linking

LQ Lab Series 2.1: Master and Member Group-Linking

 

 

Screenshot 2026-09-01 at 12.17.10.png

Before You Start

  • Both LQ units are powered on.

  • Both LQ units are connected to the network and have confirmed IP addresses.

  • CCM access works for both LQ units from the PC or laptop.

  • Both LQ units are on the same subnet or VLAN, or routing is configured between them.

  • The Link-Master IP address is known.

  • The Link-Master uses a static IP address or DHCP reservation where possible.

  • Both LQ units are running compatible software versions.

Important: Do not start until both LQ units have confirmed IP setup and CCM access.

For help with network access, see:

LQ Lab Series 1.2 - Initial IP Setup and CCM Access

LQ Lab Series 1.3: Setting a Static IP

Link-Master and Link-Member Overview

Linking creates one LQ Link-Group. One unit acts as the Link-Master, and the other unit joins as the Link-Member.

Term

Meaning

Term

Meaning

LQ Link-Group

A group of linked LQ devices. One device must be the Link-Master.

Link-Master

The main LQ that manages the Link-Group and shares configuration information with linked members.

Link-Member

The LQ that joins the Link-Group by pointing to the Link-Master IP address or hostname.

Stable linking

Use a static IP address or DHCP reservation for the Link-Master. If its IP address changes, members may lose connection.

Link-Group size

A Link-Group can contain up to 6 devices total. For an LQ-only setup, this means up to 6 LQ units in one Link-Group.

Important notes:

  • A Link-Group must have one Link-Master.

  • If the Link-Group is locked by default, unlock it before adding a member. Lock it again after linking if required.

  • When a member joins a Link-Group, its existing configuration may be replaced by the master configuration.

STEP 1: Configure Link-Master

Screenshot 2026-09-01 at 12.13.39.png
Screenshot 2026-09-01 at 12.15.26.png

On LQ #1 (Master)

  1. Open CCM using the LQ IP address.

  2. Go to Device > Linking.

  3. Confirm that Link-Group Role is set to Link-Master.

  4. If the Link-Group state is Locked, change it to Unlocked before adding the member.

  5. Open the network settings and record the Link-Master IP address.

Example:

LQ #1 role: Link-Master LQ #1 IP: 192.168.1.40

 

STEP 2: Configure Link-Member

Screenshot 2026-09-01 at 12.21.35.png

On LQ #2 (Member)

  1. Open CCM using the LQ IP address.

  2. Go to Device > Linking.

  3. Set Link-Group Role to Link-Member.

  4. Enter the Link-Master IP address or hostname.

  5. Select an available device ID if required.

  6. Apply the changes.

  7. Wait for the link process to complete.

 

STEP 3: Verify the Link-Group:

Screenshot 2026-08-19 at 15.04.54.png
  1. Open the CCM Overview page.

  2. Confirm that both LQ units appear in the same Link-Group.

  3. Confirm that one unit shows as Link-Master.

  4. Confirm that the second unit shows as Link-Member.

  5. Confirm that both IP addresses are correct.

  6. Lock the Link-Group again if required.

Success check

The linking step is successful when both LQ units appear in the CCM Overview page, one is the Link-Master, the other is the Link-Member, no link error is shown, and the Link-Member can reach the Link-Master.

Common Problems and First Checks

Problem

Check first

Problem

Check first

Link-Member cannot join

Confirm the Link-Master IP address or hostname is correct.

Check whether the Link-Group is locked.

Link-Member shows a lost connection

Confirm that the Link-Master is powered, reachable, and on the correct subnet or VLAN.

Link-Master is not accepting members

Check whether the Link-Group is locked

Wrong or duplicate device ID

Select a different available device ID and apply the change again.

Link works, but audio does not pass

Linking does not automatically route audio.

Check Channel Assignment routing

Link breaks after reboot or later use

Confirm that the Link-Master has a static IP address or DHCP reservation.

What This Step Does Not Do

This step links the LQ units into one Link-Group. It does not automatically route audio between ports. After the LQ units are linked, ports still need to be assigned to channels.

Do not troubleshoot audio routing until both LQ units are visible in the same Link-Group.

 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.