Matrix: How to Move an E-IPA Card to Another Slot
Use this procedure to move an E-IPA card configuration to a different slot in an Eclipse frame without rebuilding the card manually.
Question:
How can an E-IPA card be moved to another slot in an Eclipse Median frame without manually rebuilding the card configuration?
Answer:
In EHX 13.0 (or later), the Move option may not appear because Allow Move and Paste cards is disabled by default.
To enable the Move Card feature, you will have to go to Settings to enable this feature.
Steps
1. Enable Move and Paste
Open EHX.
Go to Tools > Settings.
Check/Tick - Allow Move and Paste cards.
Click OK.
2. Move the card configuration
Open the Cards and Ports page.
Right-click the E-IPA card in its current slot.
Select Move.
Right-click the destination slot.
Select Paste.
3. Move the physical card
Move the physical front card to the corresponding slot.
Apply Map to Matrix or Ctrl + D for the change to take effect.
Warning: If the rear card also needs to be moved, shut down the matrix first.
Rear cards are not hot-pluggable.
Important Notes
Save the current EHX configuration before starting.
Make sure the destination slot is available.
After moving the card in EHX, move the physical front card to the matching slot and Apply Map to Matrix or Ctrl + D.
Result
The E-IPA card configuration is moved to the new slot without having to recreate the full card configuration manually.