Matrix: PSU Module failiure not displayed in EHX-Monitoring

Matrix: PSU Module failiure not displayed in EHX-Monitoring

 Problem

A PSU failure LED is lit on the alarm module but EHX monitoring page does not display a PSU related error

 Solution

Reason for that is the system architecture and missing messaging across the backplane in case of Median and Omega frames.

  1. EHX Monitoring will only display PSU failures on Pico and Delta frames

  2. Omega or Median frames will always display both PSU1 and PSU2 as good

  3. Same is true for the Event-Log

  4. In case of Median and Omega please rely solely on the alarm module LEDs

 

EHX Event-Log and Monitoring only detects and displays PSU failures on Pico and Delta frames

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.