Is it possible ?? to configure the NMOS registry server IP manually as the E-IPA card is not being recognized by the NMOS controller

 

Yes using EHX v14.1 or higher you can set the NMOS registry IP address manually 

Goto the E-IP Acard properties 

note when you set a card to NMOS mode 

  1. the whole card is set into NMOS mode and only supports ST2110-30 audio streams 

  2. the number of channels per stream (1, 2, 4, 8) is fixed for all streams across the whole card  

 

image-20251202-124009.png

using EHX v14.1 the NMOS control data is in-band and on the same subnet as the ST2110-30 audio

Clear-Com plan to allow the user to set the NMOS control data IP address to be out-band in later versions

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.