Wireless: My FSII IP Antenna is not connecting to my system
We’ve been having issues with our FSII BP, where audio is not heard clearly both ways ,
After investigating this issue we came across the following error message on the Arcadia :
“PTP maximum offset from reference is above error level.”
From Customer : we did the following to resolve the problem
Rebooted Arcadia and both network switches,
Swapped faulty Antenna`s from its normal location to be on the same switch as the Arcadia AES67 LAN port (it worked fine when using a 3m CAT5 patch cable directly on the switch)
When moving the unit back to its normal location we found the following issues as we traced back the cabling
A bad RJ45 connection in a patch cable cabinet was found and replaced,
This solved the error and the TCVR came online again.
This connector was faulty at times.
Fiber connection between Main Eth-Switch in rack room and Eth-Switch 2nd control room was faulty, shortly bended patch cable & LC connector not fully joined probably provoked the issue. Patch cord replaced and firmly connected, Fiber connection between switches is tested and now OK.
Since this is resolved we aren`t experiencing the before mentioned faults ‘PTP Max offset from reference’ or ‘PTP Mean path delay’
Other common tips when troubleshooting
To ensure minimum delay of the PTP clock and audio packets across the network we recommend the use of QoS, IGMP and VLANS within IT networks
Make sure the QoS. IGMP and VLANs are setup the same on all switches , with one switch set as IGMP querier.
The use of dedicated inter-switch trunk ports to carry only AES67 traffic. Alternately the establishment of a dedicated switch network should be considered for FreeSpeak IPTs
Offset From Leader | Roaming experience |
Less Than ± 500ns | Optimal |
± 500ns | Potential for issues |
± 1000ns | Issues with roaming |
Greater than ± 1000ns | Can not Roam |
see Click here AES67 AoIP Guide PDF and
Network Switches that DO and DO NOT Work with Clear-Com AES67/ST2110-30