Matrix: How to Link LQ to E-IPA and (SIP Server) Grandstream UCM6202
This guide provides step-by-step instructions to set up SIP linking between a Clear-Com LQ device, an Eclipse E-IPA card, and a Grandstream UCM6202 SIP server.
Pre-Requisites
Before you begin, make sure you have the following login credentials and network information:
*Terminology may vary from depending on the SIP server manufacturer
SIP Server Credential:
SIP IP Address
SIP User Caller ID / Extension
SIP Password
IPA Card Credential:
IPA IP Address
Username
Password
Part 1: Linking LQ to Eclipse E-IPA
Step 1: LQ SIP Port Configuration (EHX):
Open EHX.
Go to Cards & Ports > E-IPA
Click “+” to create a new port.
Set Port Type = SIP (LQ) and give it a “Label”
Under IP Port Options:
Enter User ID and Password (e.g lq1 & 1234)
Apply Map To Matrix (CTRL + D)
Step 2: LQ Configuration via CCM (Core Configuration Manager)
Log in to LQ CCM.
Navigate to Accounts > IVD.
Click “+” to add a new IVD
Remote System Settings:
Give it a Label
Enter IP/Hostname = IP Address of E-IPA
Enter Port = 6001.
Port Setting - Add Port
Give a Label
Enter User ID & Password (e.g lq1 &1234)
Select LQ Assignment.
Verification: Once the connection is established successfully, the status indicator will turn
Part 2: Linking LQ to Grandstream UCM6202 (SIP Server)
Step 1: Configure SIP Server Extension
Create a new SIP extension on your Grandstream UCM6202 via web GUI. See - Grandstream SIP Server
Note down the Extension/User ID, Password (e.g 1001 & 1234), and SIP Server IP Address. This will be used in Step 2.
Step 2: Configure LQ SIP Account in CCM
In LQ CCM, go to Accounts > SIP.
Under SIP Server Settings:
Label, Proxy IP/Hostname = SIP Server IP, Proxy Port = 5060.
Click “+” Account: Label, User (Extension), Password (e.g 1001 & 1234), and LQ Assignment.
Verification: Once connected, the SIP Account Status in LQ CCM will show Green (Registered).