Eclipse : IPT's losing connection once an hour, on the hour

Eclipse : IPT's losing connection once an hour, on the hour

If losing connection with IPT’s but the IPA card appears to be solid, consider looking at the IP settings of the IPA card.

If you have

  • Admin/IVC set to Lan 1 for example and sharing the same IP address,

  • AoIP set to Lan 3 but also on the same switch,

But the AOIP data is using the SAME VLan and subnet as your Admin/IVC, then you could be creating an IP loop or storm, depending on how the switch handles the traffic.

Best way to fix this is to also set AoIP to Lan 1, which means it is using the same Lan port as Admin/IVC.

Also consider removing the ethernet connection from Lan 3 and stick with a single ethernet connection to the switch. This should remove any potential network loops and reduce the chances of your switch shutting down a port.

 

Clear-Com mandates you use the following E-IPA Lan port connections

Admin/ IVC connections == Lan 1 == VLAN #1

 

AES67 connections == Lan 3 == VLAN #2

  • with different subnet compared to Lan 1 with correct QoS and IGMP settings

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.