Edge: Edge BPs not connecting after upgrade to v6.6.79

Edge: Edge BPs not connecting after upgrade to v6.6.79

I recently upgraded my Edge BPs from v5.4.79 to v6.6.79

after the upgrade the Edge BPs would no longer connect to the system

 

Answer : Unfortunately the OLD Edge BP  + IPT firmware is not compatible with the NEW Edge BP + IPT firmware. There was a change in the radio firmware which stop them being compatible

 

OLD Firmware

NEW Firmware

 

OLD Firmware

NEW Firmware

 

Edge BP = v5.4.79

Edge BP = v6.6.79

Edge BP v6.6 not compatible with IPT v4.29
MUST use v6.6 FS Edge BP with IPT v5.10
FreeSpeak Edge Beltpacks must be upgraded (first) before the transceivers. If the transceivers have been upgraded you will only be able to upgrade beltpacks using the Clear-Com FS Icon / Edge Beltpack Firmware Update utility.

Edge IPT = v4.29.77

Edge BP = v5.10.77

IPT Ver v5.10 not compatible with Edge BP v5.4
MUST use v6.6 FS Edge BP with IPT v5.10
FreeSpeak Edge Beltpacks must be upgraded (first) before the transceivers. If the transceivers have been upgraded you will only be able to upgrade beltpacks using the Clear-Com FS Icon / Edge Beltpack Firmware Update utility.

 

 

 

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.