LQ: Trigger GPO via Control Event

“Using a Agent-IC client connected to a LQ-GPIO unit. My customer wants to talk out into the PA system of 2 different zones in a railway station, and at the same time, he also wants a relay GPO to be activated. Using a LQ-4WG2 and an AGENT-IC Client, with 2 channels, attached to 2 different 4W ports to distribute the audio to the 2 different PA system. But during the tests, I face an issue with the GPO part:
 

  • On LQ, it is not possible, at the same time and with the same button, to activate a GPO AND a talk function, right the Agent IC client. There is no stack key option or “GPO control by button press” in the LQ world

 

Solution : Correct - it is not possible to stack keys on the Agent IC client when its connected to a LQ device. The closest configuration to this would be a latching/latched talk key paired with a Control Event key on the same keyset (as in Channel 1 in the example below.)

Screenshot_20240118_131240_Agent-IC.jpg

 

  • So I though about splitting the audio output from the 4W port of the LQ unit, and send it to the PA system AND at the same time loop it back in a spare 4W input, to activate the VOX function and the “vox action triggers”. It works, and we can see the control button on the AGENT-IC is switched ON (screenshot 1). BUT the GPO is not activated, even if it is set to be control by “control event 1”.

It is not possible to trigger a GPO from the same 4w port where a Vox trigger is set. In order to work around this, you can move your GPO trigger to a separate port and assign that port to the same channel. This way, when a Control Event is triggered by VOX on Port X, the GPO on Port Y will be triggered as long as they are in the same channel.

In the example below, audio from the output of "3-4W-Port-F" is fed into the input of "3-4W-Port-G". See the pdf at the bottom of this page for a diagram of the set up.

Screenshot 2024-01-18 134338.png

 

“3-4W-Port-G” will send a Control Event 2 in Channel 2 when the Vox threshold is reached.

Screenshot 2024-01-18 134404.png

When Control Event 2 is active in Channel 2, the GPO will be triggered on "3-4W-Port-H".

Screenshot 2024-01-18 134417.png

 

Set up diagram:

Looking for labels? They can now be found in the details panel on the floating action bar.

Related content

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..


The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.