AOIP: Basic NMOS troubleshooting
EHX v13.1 introduces NMOS (is-4/ is-5) functionality for E- IPA cards
See What's NMOS | AMWA – home of JT-DMF & NMOS for overview
see
Easy-NMOS for testing NMOS using Easy-NMOS
NMOS allows a 3rd party controller to set up routes between AES67 devises
Each AES67 device/ node publishes it capabilities to the controller , can then make and & break routes AES67 streams without them have to exchange SDP files
troubleshooting
follow standard AES67 and PTP troubleshooting steps
use tools like PTP trackhound , Multi-cast Hammer , Wireshark to assit you
check NMOS controller:
Clearcom MQTT broker port is 8855,check if the nmos controller includes 8855 port.
check E-IPA reports same state as NMOS controller
if card not in NMOS controller, web browser to <CARD-IP-ADDRESS>:8855 ->
if you see the NMOS tree (standard XML output) then the IPA card is correctly enabled .
If it times out... check your EHX config, IPA card is in NMOS mode, check IP address/ subnet mask of your AOIP LAN port, and the IPA card is running the correct firmware. This should be V13.1 or later to support NMOS mode