How do I activate a relay on an HRM-4X remote station using the SA button?

Relay activation by way of the SA (stage announce) button can be configured from the front panel of the remote station as well as the CCM (core configuration manager).
From the front panel press the menu button. Select audio settings in the first window, select SA/Audio Out in the second window, select mode in the third window, select SA in the fourth window and press the fourth encoder to engage the option. 

From the front panel press the menu button. Select Control I/O in the first window, select Outputs in the second window, Relay 1 in the third window, select SA in the fourth window and press the fourth encoder to engage the option. 
From the CCM you can change the SA function on the HRM-4X after it has been assigned a role. Select the Roles tab. Under Stage Announce Output drop down menu go to Mode: and select SA.
Go the GPO (Relay) drop down menu. Under Relay 1 section Go to Local Key Assignment and select SA Key.

CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT


This solution was provided to you by Clear-Com via a question submitted to us by customers like you. If your question wasn’t answered, you need help or you have a recommended solution for our database, please send us an email at support@clearcom.com

The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.