Broaman:
Would you be able give me advice on product selection on the following….based on the BroaMan range
- 30x SDI feeds send – from OB van to VAR room
- 4x SDI return feeds – from VAR room to OB Van
Obviously we will need the RX and TX ends
It needs to be multiplexed, ideally down 1 fibre if feasible….but I get it might have to be 2 or more
Solution: use the following items
One of each will give you 30 channels in one direction (all of the R48-24 and 6 of the R48-12 channels) and 4 returns (from the remaining 6 of the R48-12) and one spare dual module.
Each box needs a duplex fibre.
Repeat48-12 |
|
Repeat48-24 |
|
OB Van | VAR Room | |
R48-24 | --> | R48-24 |
R48-12 (6 inputs) (6 outputs) | --> <-- | R48-12 (6 outputs) (6 inputs) |
CAN'T FIND YOUR ANSWER? CLICK HERE TO CONTACT SUPPORT
This solution was provided by Clear-Com via a question submitted to us by customers like you. If you wish to share with us a new solution or update an old one, please follow this link..
The information on this page is owned by Clear-Com and constitutes Clear-Com’s confidential and proprietary information, may be used solely for purposes related to the furtherance of Clear-Com’ business and shall not be disclosed, distributed, copied or disseminated without Clear-Com’s prior written consent. Click Here for Clear-Com's privacy statement.